Configure Advanced Functions
Configure advanced access control functions such as multi-factor authentication, anti-passback, custom Wiegand rules, and device parameters.
You can configure the advanced functions of access control to meet some special requirements in different scenes, such as multi-factor authentication, anti-passback, etc.
- For the card related functions (the type of access control card/multi-factor authentication), only the card(s) with access group applied will be listed when adding cards.
- The advanced functions should be supported by the device.
- Hover the cursor on the Advanced Function, and then click to customize the advanced function(s) to be displayed.
Configure Device Parameters
After adding the access control device, you can configure the parameters of access control device (access controller), access control points (door or floor), alarm inputs, alarm outputs, card readers and lane controller.
Configure Parameters for Access Control Device
After adding the access control device, you can configure its parameters, including overlaying user information on picture, uploading pictures after capturing, saving captured pictures, etc.
Before You Start
Add access control device to the client.
Steps
-
Click Access Control → Advanced Function → Device Parameter.
If you cannot find Device Parameter in the Advanced Function list, hover the cursor on the Advanced Function, and then click to select the Device Parameter to be displayed.
-
Select an access device to show its parameters on the right page.
-
Turn the switch to ON to enable the corresponding functions.
- The displayed parameters may vary for different access control devices.
- Some of the following parameters are not listed in the Basic Information page; click More to edit the parameters.
RS-485 Comm. Redundancy — You should enable this function if you wire the RS-485 card reader to the access control device redundantly.
Display Detected Face — Display face picture when authenticating.
Display Card Number — Display the card information when authenticating.
Display Person Information — Display the person information when authenticating.
Overlay Person Info. on Picture — Display the person information on the captured picture.
Voice Prompt — If you enable this function, the voice prompt is enabled in the device. You can hear the voice prompt when operating in the device.
Upload Pic. After Linked Capture — Upload the pictures captured by linked camera to the system automatically.
Save Pic. After Linked Capture — If you enable this function, you can save the picture captured by linked camera to the device.
Press Key to Enter Card Number — If you enable this function, you can input the card No. by pressing the key.
Wi-Fi Probe — If you enable this function, the device can probe the surrounding communication devices' MAC address and upload the MAC address to the system. If the MAC address matches the specified MAC address, the system can trigger some linkage actions.
3G/4G — If you enable this function, the device can communicate in 3G/4G network.
NFC Anti-Cloning — If you enable this function, you cannot use the cloned card for authentication and further enhance security.
-
Click OK.
-
Optional: Click Copy to, and then select the access control device(s) to copy the parameters in the page to the selected device(s).
Configure Parameters for Door/Elevator
After adding the access control device, you can configure its access point (door or floor) parameters.
Before You Start
Add access control device to the client.
Steps
-
Click Access Control → Advanced Function → Device Parameter.
-
Select an access control device on the left panel, and then click to show the doors or floors of the selected device.
-
Select a door or floor to show its parameters on the right page.
-
Edit the door or floor parameters.
- The displayed parameters may vary for different access control devices.
- Some of the following parameters are not listed in the Basic Information page; click More to edit the parameters.
Name — Edit the card reader name as desired.
Door Contact — You can set the door sensor as remaining closed or remaining open. Usually, it is remaining closed.
Exit Button Type — You can set the exit button as remaining closed or remaining open. Usually, it is remaining open.
Door Locked Time — After swiping the normal card and relay action, the timer for locking the door starts working.
Extended Open Duration — The door contact can be enabled with appropriate delay after a person with extended access needs swipes her/his card.
Door Left Open Timeout Alarm — The alarm can be triggered if the door has not been closed in a configured time period. If it is set as 0, no alarm will be triggered.
Lock Door when Door Closed — The door can be locked once it is closed even if the Door Locked Time is not reached.
Duress Code — The door can open by inputting the duress code when there is duress. At the same time, the client can report the duress event.
Super Password — The specific person can open the door by inputting the super password.
Dismiss Code — Create a dismiss code which can be used to stop the buzzer of the card reader (by entering the dismiss code on the keypad).
- The duress code, super code, and dismiss code should be different.
- The duress code, super password, and the dismiss code should be different from the authentication password.
- The length of duress code, super password, and the dismiss code is according to the device; usually it should contain 4 to 8 digits.
-
Click OK.
-
Optional: Click Copy to, and then select the door/floor(s) to copy the parameters in the page to the selected doors/floor(s).
The door or floor's status duration settings will be copied to the selected door/floor(s) as well.
Configure Parameters for Card Reader
After adding the access control device, you can configure its card reader parameters.
Before You Start
Add access control device to the client.
Steps
-
Click Access Control → Advanced Function → Device Parameter.
-
In the device list on the left, click to expand the door, select a card reader and you can edit the card reader's parameters on the right.
-
Edit the card reader basic parameters in the Basic Information page.
- The displayed parameters may vary for different access control devices. There are part of parameters listed as follows. Refer to the user manual of the device for more details.
- Some of the following parameters are not listed in the Basic Information page; click More to edit the parameters.
Name — Edit the card reader name as desired.
OK LED Polarity / Error LED Polarity / Buzzer Polarity — Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the card reader parameters. Generally, adopt the default settings.
Minimum Card Swiping Interval — If the interval between card swiping of the same card is less than the set value, the card swiping is invalid. You can set it as 0 to 255.
Max. Interval When Entering PWD — When you input the password on the card reader, if the interval between pressing two digits is larger than the set value, the digits you pressed before will be cleared automatically.
Alarm of Max. Failed Attempts — Enable to report alarm when the card reading attempts reach the set value.
Max. Times of Card Failure — Set the max. failure attempts of reading card.
Tampering Detection — Enable the anti-tamper detection for the card reader.
Communicate with Controller Every — When the access control device cannot connect with the card reader for longer than the set time, the card reader will turn offline automatically.
Buzzing Time — Set the card reader buzzing time. The available time ranges from 0 to 5,999s. 0 represents continuous buzzing.
Card Reader Type / Card Reader Description — Get card reader type and description. They are read-only.
Fingerprint Recognition Level — Select the fingerprint recognition level in the drop-down list.
Default Card Reader Authentication Mode — View the default card reader authentication mode.
Fingerprint Capacity — View the maximum number of available fingerprints.
Existing Fingerprint Number — View the number of existed fingerprints in the device.
Score — The device will score the captured picture according to the yaw angle, pitch angle, and pupillary distance. If the score is less than the configured value, face recognition will fail.
Face Recognition Timeout Value — If the recognition time is more than the configured time, the device will remind you.
Face Recognition Interval — The time interval between two continuous face recognitions when authenticating. By default, it is 2s.
Face 1:1 Matching Threshold — Set the matching threshold when authenticating via 1:1 matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate when authenticating.
1:N Security Level — Set the matching security level when authenticating via 1:N matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate when authenticating.
Live Face Detection — Enable or disable the live face detection function. If enabling the function, the device can recognize whether the person is a live one or not.
Live Face Detection Security Level — After enabling Live Face Detection function, you can set the matching security level when performing live face authentication.
Max. Failed Attempts for Face Auth. — Set the maximum live face detection failed attempts. The system will lock the user's face for 5 minutes if the live face detection fails for more than the configured attempts. The same user cannot authenticate via the fake face within 5 minutes. Within the 5 minutes, the user can authenticate via the real face twice continuously to unlock.
Lock Authentication Failed Face — After enabling the Live Face Detection function, the system will lock the user's face for 5 minutes if the live face detection fails for more than the configured attempts. The same user cannot authenticate via the fake face within 5 minutes. Within the 5 minutes, the user can authenticate via the real face twice continuously to unlock.
Application Mode — You can select indoor or others application modes according to actual environment.
-
Click OK.
-
Optional: Click Copy to, and then select the card reader(s) to copy the parameters in the page to the selected card reader(s).
Configure Parameters for Alarm Input
After adding the access control device, you can configure the parameters for its alarm inputs.
Before You Start
Add access control device to the client, and make sure the device supports alarm input.
If the alarm input is armed, you cannot edit its parameters. Disarm it first.
Steps
-
Click Access Control → Advanced Function → Device Parameter.
-
In the device list on the left, click to expand the door, select an alarm input and you can edit the alarm input's parameters on the right.
-
Set the alarm input parameters.
Name — Edit the alarm input name as desired.
Detector Type — The detector type of the alarm input.
Zone Type — Set the zone type for the alarm input.
Sensitivity — Only when the duration of signal detected by the detector reaches the setting time, the alarm input is triggered. For example, if you have set the sensitivity as 10ms, only when the duration of signal detected by the detector reaches 10ms, this alarm input is triggered.
Trigger Alarm Output — Select the alarm output(s) to be triggered.
-
Click OK.
-
Optional: Click the switch on the upper-right corner to arm or disarm the alarm input.
Configure Parameters for Alarm Output
After adding the access control device, if the device links to alarm outputs, you can configure the parameters.
Before You Start
Add access control device to the client, and make sure the device supports alarm output.
Steps
-
Click Access Control → Advanced Function → Device Parameter to enter access control parameter configuration page.
-
In the device list on the left, click to expand the door, select an alarm output and you can edit the alarm output's parameters on the right.
-
Set the alarm output parameters.
Name — Edit the alarm output name as desired.
Alarm Output Active Time — How long the alarm output will last after triggered.
-
Click OK.
-
Optional: Set the switch on the upper right corner to ON to trigger the alarm output.
Configure Parameters for Lane Controller
After adding the lane controller to the client, you can configure its parameters for passing through the lane.
Before You Start
Add access control device to the client.
Steps
-
Click Access Control → Advanced Function → Device Parameter to enter Parameter Settings page.
-
In the device list on the left, select a lane controller and you can edit the lane controller's parameters on the right.
-
Edit the parameters.
Passing Mode — Select the controller which will control the barrier status of the device.
- If you select According to Lane Controller's DIP Settings, the device will follow the lane controller's DIP settings to control the barrier. The settings on the software will be invalid.
- If you select According to Main Controller's Settings, the device will follow the settings of the software to control the barrier. The DIP settings of the lane controller will be invalid.
Free Passing Authentication — If you enable this function, when both entrance and exit's barrier mode is Remain Open, the pedestrians should authenticate each time passing through the lane. Otherwise an alarm will be triggered.
Opening/Closing Barrier Speed — Set the barrier's opening and closing speed. You can select from 1 to 10. The greater the value, the faster the speed.
The recommended value is 6.
Audible Prompt Duration — Set how long the audio will last, which is played when an alarm is triggered.
0 refers to the alarm audio will be played until the alarm is ended.
Temperature Unit — Select the temperature unit that displayed in the device status.
-
Click OK.
Configure Remaining Open/Closed
You can set the status of the door as open or closed and set the elevator controller as free and controlled. For example, you can set the door remaining closed in the holiday, and set the door remaining open in the specified period of the work day.
Before You Start
Add the access control devices to the system.
Steps
-
Click Access Control → Advanced Function → Remain Open/Closed to enter the Remain Open/Closed page.
-
Select the door or elevator controller that needs to be configured on the left panel.
-
To set the door or elevator controller status during the work day, click the Week Schedule and perform the following operations.
-
For door, click Remain Open or Remain Closed.
-
For elevator controller, click Free or Controlled.
-
Drag the cursor to draw the time duration, which means in that duration of time, the configured access group is activated.
Up to 8 time durations can be set to each day in the week schedule.
-
Optional: Perform the following operations to edit the time durations.
- Move the cursor to the time duration and drag the time duration on the timeline bar to the desired position when the cursor turns to the move icon.
- Click the time duration and directly edit the start/end time in the appeared dialog.
- Move the cursor to the start or the end of time duration and drag to lengthen or shorten the time duration when the cursor turns to the resize icon.
-
Click Save.
Related Operation Description Copy to Whole Week Select one duration on the time bar, click Copy to Whole Week to copy all the duration settings on this time bar to other week days. Delete Selected Select one duration on the time bar, click Delete Selected to delete this duration. Clear Click Clear to clear all the duration settings in the week schedule. -
-
To set the door status during the holiday, click the Holiday and perform the following operations.
-
Click Remain Open or Remain Closed.
-
Click Add.
-
Enter the start date and end date.
-
Drag the cursor to draw the time duration, which means in that duration of time, the configured access group is activated.
Up to 8 time durations can be set to one holiday period.
-
Perform the following operations to edit the time durations.
- Move the cursor to the time duration and drag the time duration on the timeline bar to the desired position when the cursor turns to the move icon.
- Click the time duration and directly edit the start/end time in the appeared dialog.
- Move the cursor to the start or the end of time duration and drag to lengthen or shorten the time duration when the cursor turns to the resize icon.
-
Optional: Select the time duration(s) that need to be deleted, and then click the delete icon in the Operation column to delete the selected time duration(s).
-
Optional: Click the clear icon in the Operation column to clear all the time duration(s) in the time bar.
-
Optional: Click the delete icon in the Operation column to delete this added holiday period from the holiday list.
-
Click Save.
-
-
Optional: Click Copy to to copy the door status settings of this door to other door(s).
Configure Multi-Factor Authentication
You can manage the persons by group and set the authentication for multiple persons of one access control point (door).
Before You Start
Set access group and apply the access group to the access control device. For details, refer to Set Access Group to Assign Access Authorization to Persons. Perform this task when you want to set authentications for multiple cards of one access control point (door).
Steps
-
Click Access Control → Advanced Function → Multi-Factor Auth.
-
Select an access control device in device list on the left panel.
-
Add a person/card group for the access control device.
-
Click Add on the right panel.
-
Create a name for the group as desired.
-
Specify the start time and end time of the effective period for the person/card group.
-
Select member(s) and card(s) in the Available list, and the selected member(s) and card(s) will be added to the Selected list.
Make sure you have issued a card to the person. Make sure you have set access group and applied the access group to the access control device successfully.
-
Click Save.
-
Optional: Select the person/card group(s), and then click Delete to delete it/them.
-
Optional: Select the person/card group(s), and then click Apply to re-apply access group that failed to be applied previously to the access control device.
-
-
Select an access control point (door) of the selected device on the left panel.
-
Enter the maximum interval when entering password.
-
Add an authentication group for the selected access control point.
-
Click Add on the Authentication Groups panel.
-
Select a configured template as the authentication template from the drop-down list.
For setting the template, refer to Configure Schedule and Template.
-
Select the authentication type as Local Authentication, Local Authentication and Remotely Open Door, or Local Authentication and Super Password from the drop-down list.
Local Authentication — Authentication by the access control device.
Local Authentication and Remotely Open Door — Authentication by the access control device and by the client. When the person swipes the card on the device, a window will pop up. You can unlock the door via the client.
You can check Offline Authentication to enable the super password authentication when the access control device is disconnected with the client.
Local Authentication and Super Password — Authentication by the access control device and by the super password.
-
Select the added person/card group in the left list below and it will be added to the Selected list on the right as the authentication group.
-
Click the added authentication group in the right list to set authentication times in the Auth Times column.
- The authentication times should be larger than 0 and smaller than the added personnel quantity in the personnel group.
- The maximum value of authentication times is 16.
-
Click Save.
- For each access control point (door), up to four authentication groups can be added.
- For the authentication group of which authentication type is Local Authentication, up to 8 person/card groups can be added to the authentication group.
- For the authentication group of which authentication type is Local Authentication and Super Password or Local Authentication and Remotely Open Door, up to 7 person/card groups can be added to the authentication group.
-
-
Click Save.
Configure Custom Wiegand Rule
Based on the knowledge of uploading rule for the third party Wiegand, you can set multiple customized Wiegand rules to communicate between the device and the third party card readers.
Before You Start
Wire the third party card readers to the device.
- By default, the device disables the custom Wiegand function. If the device enables the custom Wiegand function, all Wiegand interfaces in the device will use the customized Wiegand protocol.
- Up to 5 custom Wiegands can be set.
- For details about the custom Wiegand, see Custom Wiegand Rule Descriptions.
Steps
-
Click Access Control → Advanced Function → Custom Wiegand to enter the Custom Wiegand page.
-
Select a custom Wiegand on the left.
-
Create a Wiegand name.
Up to 32 characters are allowed in the custom Wiegand name.
-
Click Select Device to select the access control device for setting the custom Wiegand.
-
Set the parity mode according to the property of the third party card reader.
- Up to 80 bits are allowed in the total length.
- The odd parity start bit, the odd parity length, the even parity start bit and the even parity length range from 1 to 80 bit.
- The start bit of the card ID, the manufacturer code, the site code, and the OEM should range from 1 to 80 bit.
-
Set output transformation rule.
-
Click Set Rule to open the Set Output Transformation Rules window.
-
Select rules on the left list. The selected rules will be added to the right list.
-
Optional: Drag the rules to change the rule order.
-
Click OK.
-
In the Custom Wiegand tab, set the rule's start bit, length, and the decimal digit.
-
-
Click Save.
Configure Card Reader Authentication Mode and Schedule
You can set the passing rules for the card reader of the access control device according to your actual needs.
Steps
-
Click Access Control → Advanced Function → Authentication to enter the authentication mode configuration page.
-
Select a card reader on the left to configure.
-
Set card reader authentication mode.
-
Click Configuration.
PIN refers to the PIN code set to open the door. Refer to Configure Access Control Information.
-
Check the modes in the Available Mode list and they will be added to the selected modes list.
-
Click OK. After selecting the modes, the selected modes will display as icons with different color.
-
-
Click the icon to select a card reader authentication mode, and drag the cursor to draw a color bar on the schedule, which means in that period of time, the card reader authentication is valid.
-
Repeat the above step to set other time periods.
-
Optional: Select a configured day and click Copy to Week to copy the same settings to the whole week.
-
Optional: Click Copy to to copy the settings to other card readers.
-
Click Save.
Configure Person Authentication Mode
You can set the passing rules for persons to the specified access control device according to your actual needs.
Before You Start
- Add access control device to the client, and make sure the access control device supports the function of person authentication.
- Add person and assign access authorization to the designed person. For details, refer to Person Management and Set Access Group to Assign Access Authorization to Persons.
Steps
- Click Access Control → Advanced Function → Authentication.
- Select an access control device (that supports the function of person authentication) on the left panel to enter the person Authentication Mode page.
- Click Add to enter the Add window.
- Select the person(s) to be configured on the left panel. The selected person(s) will be added to the right panel.
- Select the authentication mode in the drop-down list of Authentication Mode.
- Click OK.
- Optional: Select person(s) on the Person Authentication mode page, and then click Apply to apply the person authentication mode to the device.
Person authentication has higher priority than other authentication modes. When the access control device has been configured with person authentication mode, the person should authenticate on this device via person authentication mode.
Configure Relay for Elevator Controller
For elevator controller, you can manage the relationship between the floor and the relay and configure the floor's relay type. Different relay types can implement different functions. By configuring the relationship between the floor and the relay, you can assign different functions to the elevator and control the elevator.
Configure Relationship between Relay and Floor
You can assign different relay types to the target floors, and each floor can be assigned with 3 relay types. By this way, you can call the elevator, and assign the operations for different floors.
Before You Start
Add the elevator controller to the client.
Steps
-
Click Access Control → Advanced Function → Elevator Configuration to enter the Relay Settings page.
-
Select an elevator controller on the left.
-
Select an unconfigured relay in the Unconfigured Relay panel on the right.
There are three types of relay available:
Button — Control the validity for buttons of each floor (represented by the button relay icon).
Call Elevator — Control to call the elevator to go to the specified floor by indoor station or outdoor station (represented by the call elevator relay icon).
Auto — Control to press the button when the user swipes card inside the elevator. The button of the floor will be pressed automatically according to the user's permission (represented by the auto button relay icon).
-
Configure the relationship between the relays and the floors.
- Drag the unconfigured relay from the Unconfigured Relay panel to the target floor in the Floor List panel.
- Drag the relay from the Floor List panel to the Unconfigured Relay panel.
- Drag the relay from one floor to another floor in the Floor List panel. If the target floor has already configured a relay of the same type as the dragged one, it will replace the existing one of the same type.
- An elevator controller can link to up to 24 distributed elevator controllers. A distributed elevator controller can link up to 16 relays.
- By default, the relay total amount is the added floor number × 3 (three types of relay).
- Up to 3 types of relay can be dragged to one floor.
- If you change the floor number in the door group management, all relays in the Relay Settings interface will restore to the default settings.
-
Click Save to apply the settings to the selected elevator controller.
Configure Relay Type
To implement different functions, you can configure different relay types, including: button relay, call elevator relay and auto button relay. The button relay controls the validity for buttons of each floor. The call elevator relay calls the elevator to the specified floor by indoor station or outdoor station. The auto button relay controls pressing the button when the user swipes card inside the elevator; the button of the floor will be pressed automatically according to the user's permission.
Steps
-
Click Access Control → Advanced Function → Elevator Configuration to enter the Relay Settings page.
-
Select an elevator controller on the left of the page.
-
Click Relay Type Settings to open the Relay Type Settings window.
- All relays in the Relay Type Settings window are unconfigured relays.
- Three types of relay are available: button relay, call elevator relay, and auto button relay.
-
Drag the relay from one relay type panel to the target one.
-
Click OK.
Configure First Person In
You can set multiple first persons for one access control point. After the first person is authorized, it allows multiple persons to access the door or other authentication actions.
Before You Start
- Add access control device to the client, and make sure the device supports the first person in function.
- Add person and assign access authorization to the designed person. For details, refer to Person Management and Set Access Group to Assign Access Authorization to Persons.
Steps
-
Click Access Control → Advanced Function → First Person In to enter the First Person In page.
-
Select an access control device in the list on the left panel.
-
Select the current mode as Enable Remaining Open after First Person, Disable Remaining Open after First Person, or Authorization by First Person from the drop-down list for each access control point of the selected device.
Enable Remaining Open after First Person — The door remains open for the configured time duration after the first person is authorized until the remain open duration ends. If you select this mode, you should set the remain open duration.
The remain open duration should be between 0 and 1440 minutes. By default, the remain open duration is 10 minutes.
Disable Remaining Open after First Person — Disable the function of first person in, i.e., normal authentication.
Authorization by First Person — All authentications (except for the authentications of super card, super password, duress card, and duress code) are allowed only after the first person authorization.
You can authenticate by the first person again to disable the first person mode.
-
Click Add on the First Person List panel.
-
Select person(s) in the left list and the person(s) will be added to the selected persons as the first person(s) of the doors. The added first person(s) will be listed in the First Person List.
-
Optional: Select a first person from the list and click Delete to remove the person from the first person list.
-
Click Save.
Configure Anti-Passback
The anti-passback feature is designed to minimize the misuse or fraudulent use of access credentials such as passing back card to an unauthorized person, or tailed access. The anti-passback function establishes a specific sequence in which access credentials must be used in order to grant access. You can set the sequence according to the actual path via the client and if the person uses the credential in wrong sequence, you can also reset the anti-passback records.
Before You Start
Add access control device to the client, and enable the anti-passing back function of the access control device.
Either the anti-passing back or multi-door interlocking function can be configured for an access control device at the same time. For the configuration of multi-door interlocking, refer to Configure Multi-door Interlocking.
Steps
-
Click Access Control → Advanced Function → Anti-Passback to enter the Anti-Passback Settings page.
-
Select an access control device on the left panel.
-
Select a card reader as the beginning of the path in the First Card Reader field.
-
Click the expand icon of the selected first card reader in the Card Reader Afterward column to open the select card reader dialog.
-
Select the afterward card readers for the first card reader.
Up to four afterward card readers can be added for one card reader.
-
Click OK in the dialog to save the selections.
-
Click Save in the Anti-Passback Settings page to save the settings and take effect.
Example: Set Card Swiping Path — If you select Reader In_01 as the beginning, and select Reader In_02, Reader Out_04 as the linked card readers. Then you can only get through the access control point by swiping the card in the order: Reader In_01, Reader In_02, and Reader Out_04.
-
Click Reset Anti-Passback and select the person(s) to delete the related anti-passback records about the person(s) on the device.
This function should be supported by the device.
Configure Multi-door Interlocking
You can set the multi-door interlocking between multiple doors of the same access control device. To open one of the doors, other doors must keep closed. That means in the interlocking combined door group, up to one door can be opened at the same time.
Before You Start
Add access control device to the client, and make sure the device supports the multi-door interlocking function.
- Multi-door Interlocking function is only supported by the access control device which has more than one access control points (doors).
- Either the anti-passing back or multi-door interlocking function can be configured for an access control device at the same time. For the configuration of anti-passing back function, refer to Configure Anti-Passback.
Steps
-
Click Access Control → Advanced Function → Multi-door Interlocking.
-
Select an access control device on the left panel.
-
Click Add on the Multi-door Interlocking List panel to open the Add Access Control Point window.
-
Select at least two access control points (doors) from the list.
Up to four doors can be added in one multi-door interlocking combination.
-
Click OK to add the selected access control point(s) for interlocking. The configured multi-door interlocking combination will be listed on the Multi-door Interlocking List panel.
-
Optional: Select an added multi-door interlocking combination from the list and click Delete to delete the combination.
-
Click Apply to apply the settings to the access control device.
Configure Authentication Code
You can configure authentication code on the client. After that, you can open the door by entering the authentication code when you forget to bring the card with you.
Before You Start
Add access control device to the client, and make sure the device supports authentication code as the authentication mode.
Steps
-
Click Access Control → Advanced Function → Authentication Code to enter the authentication code configuration page.
-
Select an access control device in the list of Controller List panel. All the applied cards and persons will display on the Card List panel.
For setting and applying the permissions to the device, refer to Set Access Group to Assign Access Authorization to Persons.
-
Click the field of each card in the Authentication Code column to enter the authentication code.
The authentication code should contain 4 to 8 digits.
-
Click Save at the upper-right corner of Authentication Code page to save the settings. The authentication code function of the card will be enabled automatically.
What to do next
You should set the card reader authentication mode of access control device as Card/Authentication Code. Refer to Configure Card Reader Authentication Mode and Schedule for details.